SLMP (also known as Mitsubishi, CC-Link, and MELSEC) is an open, Ethernet-based communication protocol developed by Mitsubishi Electric for exchanging data with programmable logic controllers (PLCs) and other industrial devices on a CC-Link or CC-Link IE network.
Request examples
Maximal
{
"action":"createInput",
"params":{
"inputName":"slmpInput1",
"serviceName":"slmp",
"tableName":"slmpTable1",
"dataCollectionIntervalMilliseconds":1000,
"dataCollectionBufferCount":5,
"dataPersistenceStrategy":"onSchedule",
"settings":{
"slmpProtocol":"tcp",
"slmpIpAddress":"192.112.100.22",
"slmpPort": 2000,
"slmpNetworkNumber":0,
"slmpDataCode":"binary",
"slmpStationNumber":255,
"slmpModuleNumber":1023,
"slmpMonitoringTimerMilliseconds":1000,
"propertyMapList":[
{
"slmpHeadDeviceNumber":200,
"slmpDeviceCode": "D",
"slmpNumberOfPoints": 1,
"slmpDataType": "short"
},
{
"slmpHeadDeviceNumber":210,
"slmpDeviceCode": "SD",
"slmpNumberOfPoints": 1,
"slmpDataType": "short"
}
]
}
},
"authToken": "replaceWithAuthTokenFromCreateSession"
}
Minimal
{
"action":"createInput",
"params":{
"inputName":"slmpInput1",
"serviceName":"slmp",
"tableName":"slmpTable1",
"settings":{
"slmpProtocol":"tcp",
"slmpIpAddress":"192.112.100.22",
"slmpPort": 2000,
"propertyMapList":[
{
"slmpHeadDeviceNumber":200,
"slmpDeviceCode": "D"
},
{
"slmpHeadDeviceNumber":210,
"slmpDeviceCode": "SD"
}
]
}
},
"authToken": "replaceWithAuthTokenFromCreateSession"
}
Properties
Request properties ("params")
| Property | Description | Default | Type | Limits (inclusive) |
|---|---|---|---|---|
serviceName |
The "serviceName" property specifies which type of input to create. |
Required - No default value | string | "slmp" |
settings |
The "settings" property specifies properties needed to configure the data source of the input. |
Optional with default of []
|
array of objects | zero or more objects |
|
settings .slmpProtocol |
The "slmpProtocol" property specifies the protocol used to connect to the SLMP (CC-Link) manager station. |
Required - No default value | string |
"tcp""udp"
|
|
settings .slmpIpAddress |
The "slmpIpAddress" property specifies the IP/hostname of the SLMP (CC-Link) manager station. |
Required - No default value | string | A valid IP address |
|
settings .slmpPort |
The "slmpPort" property specifies the IP Port for the SLMP (CC-Link) manager station. |
Required - No default value | int16 |
0 to 65535
|
|
settings .slmpNetworkNumber |
The "slmpNetworkNumber" property specifies the request destination network number (0 = Local). |
Optional with default of 0
|
int16 |
0 to 65535
|
|
settings .slmpDataCode |
The "slmpDataCode" property specifies the way data is communicated: in ASCII code or binary code. |
Optional with default of "binary"
|
string |
|
|
settings .slmpStationNumber |
The "slmpStationNumber" property specifies the device's station number. Common values include 0 to 120 for field network adapters, 125 for Control Stations, 126 for Master Stations, and 255 for direct connection to a local station. |
Optional with default of 255
|
int16 |
0 to 65535
|
|
settings .slmpModuleNumber |
The "slmpModuleNumber" property specifies the module number of the access destination . When the send destination of the request message is a multi-drop connecting station that is connected to the request destination station, set the I/O number (upper 3-digits) of the serial communication module which is performing the multi-drop connection. For the main CPU, the value is 1023. |
Optional with default of 1023
|
int16 |
0 to 65535
|
|
settings .slmpMonitoringTimerMilliseconds |
The "slmpMonitoringTimerMilliseconds" property specifies the timeout in milliseconds while reading data from the PLC.Set zero to wait forever. |
Optional with default of 2000
|
int32 | Any non-negative value |
|
settings .propertyMapList |
The "propertyMapList" property specifies properties that represent the data being requested. |
Optional with default of []
|
array of objects | One or more objects |
|
settings propertyMapList .slmpDeviceCode |
The "slmpDeviceCode" property specifies the memory of the device. For example, to read D200, specify deviceCode = "D". See "slmpDevice" Codes. |
Required - No default value | case-sensitive string |
Example Codes:
|
|
settings propertyMapList .slmpHeadDeviceNumber |
The "slmpHeadDeviceNumber" property specifies the offset/index within the memory area specified by "slmpDeviceCode". For example, to read D200, specify "slmpHeadDeviceNumber": 200. |
Required - No default value | int32 |
0 to 2147483647
|
|
settings propertyMapList .slmpNumberOfPoints |
The "slmpNumberOfPoints" property specifies the number of consecutive words to read in 2-byte Little-Endian format. |
Optional with default of 1
|
int16 |
1 to 4
|
|
settings propertyMapList .slmpDataType |
The "slmpDataType" property specifies the data type of the data retrieved by the connector. |
Optional with default of "short"
|
string |
"bool""byte""ubyte""short""ushort""long""ulong""longlong""ulonglong""float""double""string"
|
|
settings propertyMapList .slmpDataLength |
If If |
Required if "dataType" is "string"
|
integer | 1 to 32 |
|
settings propertyMapList .propertyPath |
The "propertyPath" property is a DEPRECATED property that specified the JSON path in the JSON document where the connector put the data it collected. It is mutually exclusive with the "tagName" and "tagId" properties. |
Required - No default value | string | JSON path |